PWM thermostat module with temperature sensor included for PID heating system control.

Quantity Discount You Save
2 3% Up to CHF4.14
3 6% Up to CHF12.42
4 9% Up to CHF24.84
 Customer ratings and reviews
 (4,5/5)  - 2 rating(s) - 2 review(s)
View distribution
 

PWM thermostat module with temperature sensor included for PID heating system control.

This module uses PWM (Pulse Width Modulation) to control a heater. The module features a wide range of parameters, including the  P, I and D parameters, PWM cycle duration, maximum and minimum values, and other useful options to regulate the PWM system.

The kit enables you to control a thermostatic system via your home automation box. The module will itself control your heating according to the instructions you supply. Then, based on the temperature measured by the sensor, the module will adjust the functioning of the heating system so that it meets the required temperature.

The module also offers three programmable inputs. These inputs can be bistable or monostable switches, or various sensors:

  • Input 1 can be used to enable or disable the thermostat (auto/off) or to determine the status of the heating valve via a flood detector.
  • Input 2 can be used to set the thermostat to a given (adjustable) temperature or determine the status of the heating valve via a condensation sensor.
  • Input 3 can accommodate an opening sensor with the ability to change the status of the heating valve.


The module features a number of different configurable functions:

  • The temperature instruction can be sent via the Z-Wave controller.
  • Choice of output control type: the output relay can be configured appropriately according to whether the module is connected to the heating supply (NO), or to a pilot wire input where On and Off are reversed (NC). Similarly, you can control your air conditioning, switching it on or off.
  • Upper and lower hysteresis: defines the minimum temperature difference between the set temperature and the measured temperature for the module to then switch the heating on or off accordingly.
  • Frost free mode: Specifies a minimum temperature for the heating system connected to the module. By activating this instruction, your heating will never drop below the temperature specified and prevent your pipes from freezing.


By adjusting the module output to operate as NC, you can connect it to the pilot wire input of a heater using a diode pilot wire and thus control the "Comfort" and "Off" settings of the heating.

Installation is extremely simple and enables you to connect up to 3 different switches (one to select the Auto or Off mode and 2 switches or external wired sensors that provide information from the Z-Wave groups associated with the module). You can connect the module in 230VAC (required if using the pilot wire) or 24VDC.

This an economical and environmentally-friendly module: consuming less than 0.4W, it also continuously measures the energy used at any given moment (in Watts) and the total consumption (in kWh) of the device it controls. The power consumed by these devices can therefore be recovered from your home-automation box, giving you a detailed overview of your energy consumption.

Finally, it should be noted that the QUBINO brand has set itself demanding quality and sustainability targets: for this reason they have selected high-performance components such as the OMRON relay. The numerous quality control tests carried out on the module ensure maximum durability (tough enough to operate at temperatures ranging from -10°C to 40°C).

 

Features

  • Remote control for heating
  • Fits behind an existing switch
  • PWM Thermostat Function
  • PID controller
  • A casing specifically designed for easy installation (simple cable fixings), tested by professional electricians
  • Integrates a 500 series Z-Wave chip
  • Communication 250% faster compared to standard Z-Wave devices
  • Optimised radio range
  • Very low power consumption, less than 0.4W
  • Operating temperature of -10 to 40˚C
  • Analogue temperature sensor included
  • Temperature measurement to 0.1°C
  • 3 binary inputs enable the connection of additional devices such as sensors, push or bistable buttons, etc.
  • Use to directly control a water or electric underfloor heating system, boiler, hot water pump, electric heater, etc.

 

Technical specifications

  • Power supply: 110 - 230 VAC ±10% 50/60Hz, 24-30VDC
  • Power Consumption: 0.4W
  • Rated load current of AC output (resistive load): 0.85 X 10A / 230VAC
  • Rated load current of DC output (resistive load): 0.85 X 10A / 30VDC
  • Power circuit AC output (resistive load): 200W (230VAC)
  • Power circuit DC output (resistive load): 21W (24VDC)
  • Power monitoring accuracy: +/-2W
  • Radio frequency: 868.42MHz, Z-Wave
  • Range: up to 30m indoors (depending on surrounding material)
  • Digital temperature sensor measurement range: -50 ~ 125°C
  • Operating temperature: -10 ~ 40°C
  • Space required for installation: Ø ≥ 60mm
  • Dimensions (L x H x D): 41.8 x 36.8 x 15.4mm
  • Weight: 48g
  • Temperature range of the digital sensor: -50.0 ~ 125.0°C
  • Resolution: 0.1°C
  • Length of temperature sensor cable: 1000 mm
  • Certifications: EC, RoHs
Use
Heating Management
Temperature/Humidity/CO2 Monitoring
Type
Module
Function
Actuator
Electricity Consumption
Heating
Temperature
Gateway compatibility
Homey - total compatibility
Protocol
Z-Wave Serie 500
2016-01-18

Branded products Qubino.

Accessories

Customers who bought this product also bought:

 Reviews
By on  26 July 2022 (Qubino - Z-Wave+ Flush PWM thermostat ZMNHLD1) :
(5/5

tip top

facile d'installation

By on  17 Jan. 2022 (Qubino - Z-Wave+ Flush PWM thermostat ZMNHLD1) :
(4/5

Répond parfaitment à mon attente

Inclusion avec Home Assistant sans aucun problème. Attention fiche du senseur est délicate à manipuler. Je recommande de le connecter quand on est certain du où et comment on veut l'utiliser, car le fait de brancher/débrancher le connecteur risque fortement de faire rompre les fils sur la prise.
Pour le reste, le thermostat fonctionne très bien le confort de chauffage avec mes vieux radiateurs électriques "direct" et très bon

Product added to wishlist
Product added to compare.